MODEL
RBAA
Direct-acting relief valve - pilot capacity
SERIES 2 / CAPACITY: 2 L/min. / CAVITY: T-3A
Direct-acting, pilot relief cartridges are used to remotely control the pressure setting of other pilot-operated valves.
Because capacity is limited to pilot flow, these valves should be used with other higher flow valves.
TECHNICAL DATA
Maximum Operating Pressure 350 bar
Response Time - Typical 2 ms
Maximum Valve Leakage at 110 SUS (24 cSt) 0,3 cc/min.
Adjustment - Number of Clockwise Turns to Increase Setting 5
Locknut Hex Size 15 mm
Locknut Torque 9 - 10 Nm
Seal kit - Cartridge Buna: 990-203-007
Seal kit - Cartridge EPDM: 990-203-014
Seal kit - Cartridge Polyurethane: 990-003-002
Seal kit - Cartridge Viton: 990-203-006
(L)CONTROL
L Standard Screw Adjustment
C Tamper Resistant - Factory Set
J Capped Screw Adjustment
K Handknob
O Handknob with Panel Mount
Y Tri-Grip Handknob
(A)ADJUSTMENT RANGE
A 25 - 3000 psi (1,7 - 210 bar), 1000 psi
(70 bar) Standard Setting
B 25 - 1500 psi (1,7 - 105 bar), 1000 psi
(70 bar) Standard Setting
C 25 - 6000 psi (1,7 - 420 bar), 1000 psi
(70 bar) Standard Setting
D 25 - 800 psi (1,7 - 55 bar), 400 psi (28
bar) Standard Setting
E 25 - 400 psi (1,7 - 28 bar), 200 psi (14
bar) Standard Setting
W 25 - 4500 psi (1,7 - 315 bar), 1000 psi
(70 bar) Standard Setting
(N)SEAL MATERIAL
N Buna-N
E EPDM
V Viton
MATERIAL/COATING
Standard Material/Coating
/AP Stainless Steel, Passivated
snhy.com/RBAA
TECHNICAL FEATURES
Main stage orifice is protected by a 150 micron stainless steel screen.
Suitable for use in load holding applications.
For Series 2 cartridges configured with an O control (panel mount handknob), a 1.00 in. (25,4 mm) diameter hole is required in the panel.
NOTES
Model Code Example: RBAALANCONFIGURATION OPTIONS